Search results for " renal artery"
showing 10 items of 11 documents
Stent-assisted detachable coil embolization of wide-necked renal artery aneurysms
2017
Renal artery aneurysms (RAAs) are rare with an estimated incidence of 0.1% in the general population, and they represent approximately 25% of all visceral aneurysms. The gold standard of treatment is open surgery, but it is associated with a high risk of nephrectomy, mortality, and morbidity. Less invasive endovascular therapies are becoming increasingly common for the treatment of RAAs. Here, we aimed to report three cases of wide-necked complex renal artery aneurysms treated endovascularly using stent-assisted coil embolization with self-expandable stent nitinol Solitaire AB and Concerto Axium coils. In addition, we describe the use of the waffle-cone technique in a case of wide-necked sa…
A novel NF1 mutation in a pediatric patient with renal artery aneurysm
2022
Abstract Background Neurofibromatosis type 1 (NF1) is a neurocutaneous syndrome, due to heterozygous pathogenic variants in NF1 gene. The main clinical manifestations are multiple café au lait spots, axillary and inguinal freckling, cutaneous and plexiform neurofibromas, optic glioma, Lisch nodules and osseous lesions, such as sphenoid and tibial dysplasia. Vasculopathy is another feature of NF1; it consists of stenosis, aneurysms, and arteriovenous malformations, frequently involving renal arteries. Case presentation We report on a 9-year-old girl with a novel mutation in NF1 gene and renal artery aneurysm, treated by coil embolization and complicated with hypertension. Conclusion Vasculop…
Nutcracker syndrome due to left renal vein compression by an aberrant right renal artery
2007
Classic nutcracker syndrome is caused by left renal vein compression between the superior mesenteric artery and aorta, leading to retrograde venous hypertension associated with such urinary abnormalities as hematuria or proteinuria. We describe a case of symptomatic nutcracker syndrome treated by means of stent placement in which hypertension in the left renal vein was caused by stenosis of this vein compressed by an aberrant right renal artery at a point closer to the inferior vena cava.
Impact of Accessory Renal Artery Coverage on Renal Function during Endovascular Aortic Aneurysm Repair.
2021
Background Long-term outcomes of accessory renal artery (ARA) coverage after endovascular aneurysm repair (EVAR) are unknown. We analyzed the impact of ARA coverage on renal function long-term. Methods This retrospective, monocentric study included patients treated by EVAR between 2008 and 2016. Patients with at least one ARA covered with EVAR (ARA group) were compared with patients with no covered ARA (control group). Renal function was determined by estimating the glomerular filtration rate (eGFR) and graded according to chronic kidney disease (CKD) classification stages. Results A total of 184 patients were included (ARA group, n = 25; control group, n = 159). Renal risk factors were sim…
An abdominal aortic aneurysm (AAA) in combination with duplication of the inferior vena cava (IVC), the right renal artery (RRA) and the right renal …
1990
Intra-abdominal abnormality of vessels may sometimes lead to complications. A case of the rare combination of an abdominal aortic aneurysm (AAA) at the origin of the inferior mesenteric a. with duplications of the inferior vena cava (IVC), the right renal a. (RRA) and the right renal v. (RRV) as well as absence of the left common iliac v. is reported.
Renal transplantation by automatic anastomotic device in a porcine model
2015
Automatic vascular staplers for vascular anastomoses in kidney transplantation may dramatically reduce the operative time and, in particular, warm ischemia time, thus increasing the outcome of transplantation. Ten pigs underwent kidney auto-transplantation by automatic anastomotic device. Kidneys were collected by laparotomy with selective ligations at the renal hilum and perfused with cold storage solution. To overcome the shortage in length of renal hilum, a tract of the internal jugular vein was harvested to increase the length of the vessels. The anastomoses were totally performed by the use of the anastomotic device. On 10 kidney transplants, nine were successful and no complications o…
Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneu…
2013
Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination…
Type 1A endoleak detachable coil embolization after endovascular aneurysm sealing: Case report
2021
Introduction Endovascular aneurysm sealing (EVAS) with the Nellix system was introduced to reduce endovascular aneurysm repair (EVAR) perioperative complications, especially endoleaks. Herein we report a case of successful type 1A endoleak managed with detachable coils embolization after EVAS. Presentation of case A 77-year-old male was referred for abdominal pain. The angio-CT scan confirmed the previous EVAS procedure and showed a type Is2 endoleak below the right renal artery resulting in a 2.5 cm aortic blister with contrast medium filling the space between the aortic wall and the endobags. The patient was considered unfit for conventional open surgery and an endovascular approach with …
Chimney Technique with Nellix EndoVascular Aneurysm Sealing System in a Patient with Single Kidney and Juxtarenal Abdominal Aortic Aneurysm
2016
AbstractWe present a saccular asymptomatic juxtarenal abdominal aortic aneurysm in a 70-year-old male with a very short left renal artery supplying the only kidney. The case was successfully treated with the Nellix EndoVascular Aneurysm Sealing system combined with a chimney technique.
A rare case of infrarenal aortic coarctation in a young female
2020
Abstract Introduction Infrarenal abdominal aortic coarctation (AAC) is an extremely rare disease. It can be associated with renal artery stenosis determining secondary renal hypertension. Presentation of case We report a case of AAC in young female patient presenting systemic hypertension non-responder to medical treatment. Diagnostics revealed the involvement of the right renal artery as the cause of hypertension. The management consisted of percutaneous renal artery stenting and close surveillance for the aortic segment. The treatment was uneventful with resolution of the hypertensive condition. Discussion AAC etiology is unknown. There are no studies comparing the long-term treatment out…